Design and validation of a low-cost portable hydrogen sulfide sensor for Sargassum cleanup exposure assessment
Fecha de publicación:
Autores organización
Autores
- S. Rosales-Fuerte
- J. Pech Figueroa
- S.Ramírez Said
- M. Costa
Grupos
Resumen
Hydrogen sulfide (H2S) emissions from decaying pelagic Sargassum mats in coastal regions pose both environmental and occupational health risks, underscoring the need for reliable sensors capable of storing data over time. Commercial detectors with such capabilities are often prohibitively expensive for coastal workers and field monitoring programs in impacted areas, highlighting the necessity for low-cost alternatives. In this study, we address this need by assembling, calibrating, and field-testing 15 custom-built H2S sensors (cost: US$256; resolution: 1 ppm; detection range: 0-100 ppm; recording frequency: 1 second) and by developing open-source hardware and software materials to ensure reproducibility. The factory calibration of the H2S sensors was verified and calibrated under controlled laboratory conditions using an experimental chamber and a certified Honeywell reference sensor (Honeywell BW Flex 4), since the commercial sensor modules were supplied pre-calibrated by the manufacturer. Each device underwent three independent regression trials, and the resulting mean calibration parameters demonstrated strong linearity and reproducibility. Post-calibration agreement was assessed using bias, RMSE, and Bland–Altman limits of agreement. RMSE values ranged from 0.45 to 1.28 ppm, and Bland Altman analyses showed good agreement between the calibrated sensor outputs and the Honeywell BW Flex reference measurements, with typical 95% limits of agreement of approximately ±1.3 ppm and maximum observed limits below ±2.5 ppm. Field validation was conducted in Puerto Morelos, Mexico, where the sensors were positioned at chest level for personal H2S exposure monitoring among Sargassum cleanup workers in areas with abundant decomposed Sargassum. The workers reported that the sensors did not interfere with their activities. Field measurements ranged from <1 to 22 ppm (median: 3.5 ppm), revealing elevated exposure risk that could potentially lead to adverse health effects with extended exposure and underscoring the need for continuous monitoring during cleanup operations. This study did not evaluate long-term drift, humidity, or temperature performance. For this reason, the device should be recalibrated before field campaigns and interpreted as a calibrated monitoring tool rather than as a certified occupational alarm instrument.
Datos de la publicación
- ISSN/ISSNe:
- 2468-0672,
- Tipo:
- Article
- Páginas:
- 1-16
- Enlace a otro recurso:
- www.sciencedirect.com
HardwareX Elsevier Ltd
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- Open-source hardware; Low-cost sensing; Electrochemical sensor; Macroalgae wrack; Toxic gases; Occupational hazards
Portal de investigación